National Repository of Grey Literature 13 records found  1 - 10next  jump to record: Search took 0.00 seconds. 
Comparison of effectiveness of three applications of zero-valent iron nanoparticles for remediation of groundwater polluted by chlorinated ethenes
Vacková, Nikola ; Stejskal, Vojtěch (advisor) ; Oswald, Sascha (referee)
This master's thesis is focused on remediation of groundwater polluted by chlorinated ethenes with a use of nanoiron particles. Three injections of different types of nanoiron were carried out in the contaminated area of Spolchemie a.s. company in Ústí nad Labem. The main aim of the thesis was to compare effectiveness of those three applications. The remediation of groundwater was done by direct- push injection of suspension of nanoscale zero-valent iron. After that a monitoring of groundwater level and physicochemical parameters was performed. Samples of groundwater were collected during the monitoring and were analysed for contaminants and products of dechlorination. It was discovered that NANOFER STAR nanoiron had the strongest influence on reductive dechlorination. This was reflected by concentration decrease of TCE by 84 %, VC by 60 % and total concentration of CHC by 39 % in the period three months after the injection and the increase of degradation products of chlorinated ethenes. Injections of conservative tracers potassium bromide and lithium chloride served as a criterion for differentiation between the process of dechlorination and simple dilution effect. The effectiveness of NZVI-C3 nanoiron and NANOFER STAR with CMC nanoiron were notably lower than the bare NANOFER STAR nanoiron. In...
Modelling dependence of chlorinated hydrocarbons biodegradation on changes of temperature and redox conditions in ATES sytems
Havlíková, Barbora ; Mls, Jiří (advisor) ; Datel, Josef (referee)
The Aquifer Thermal energy Storage (ATES) system is one of the most important techniques, that use the aquifer as an energy storage for heating and cooling the buildings. The operation of the ATES system is based on pumping the cold ground water into the buildings during the summer and then injecting the warmer water back into the aquifer. During the winter, the direction is reversed. Warm water is pumped to the buildings, where it serves for the heating system and then it is injected back into the aquifer. The ATES system has a main effect on the chemical composition of ground water, because of changes in the temperature of ground water, mixing of water from different redox zone and increasing of ground water flow in the neighbourhood of the wells of the ATES system. The modification in chemical composition and temperature could influence the behaviour of contaminants. If we want to install the ATES system into a contaminated aquifer, we have to know, if the ATES system would influence the behaviour of the contaminant plume positively or negatively. This study was made to increase the understanding of the dependence between changes of temperature and oxidation-reduction conditions in the ATES system and biodegradation of chlorinated hydrocarbons. In the first part, several scenarios were modelled...
Comparison of effectiveness of three applications of zero-valent iron nanoparticles for remediation of groundwater polluted by chlorinated ethenes
Vacková, Nikola
This master's thesis is focused on remediation of groundwater polluted by chlorinated ethenes with a use of nanoiron particles. Three injections of different types of nanoiron were carried out in the contaminated area of Spolchemie a.s. company in Ústí nad Labem. The main aim of the thesis was to compare effectiveness of those three applications. The remediation of groundwater was done by direct- push injection of suspension of nanoscale zero-valent iron. After that a monitoring of groundwater level and physicochemical parameters was performed. Samples of groundwater were collected during the monitoring and were analysed for contaminants and products of dechlorination. It was discovered that NANOFER STAR nanoiron had the strongest influence on reductive dechlorination. This was reflected by concentration decrease of TCE by 84 %, VC by 60 % and total concentration of CHC by 39 % in the period three months after the injection and the increase of degradation products of chlorinated ethenes. Injections of conservative tracers potassium bromide and lithium chloride served as a criterion for differentiation between the process of dechlorination and simple dilution effect. The effectiveness of NZVI-C3 nanoiron and NANOFER STAR with CMC nanoiron were notably lower than the bare NANOFER STAR nanoiron. In...
Comparison of effectiveness of three applications of zero-valent iron nanoparticles for remediation of groundwater polluted by chlorinated ethenes
Vacková, Nikola
This master's thesis is focused on remediation of groundwater polluted by chlorinated ethenes with a use of nanoiron particles. Three injections of different types of nanoiron were carried out in the contaminated area of Spolchemie a.s. company in Ústí nad Labem. The main aim of the thesis was to compare effectiveness of those three applications. The remediation of groundwater was done by direct- push injection of suspension of nanoscale zero-valent iron. After that a monitoring of groundwater level and physicochemical parameters was performed. Samples of groundwater were collected during the monitoring and were analysed for contaminants and products of dechlorination. It was discovered that NANOFER STAR nanoiron had the strongest influence on reductive dechlorination. This was reflected by concentration decrease of TCE by 84 %, VC by 60 % and total concentration of CHC by 39 % in the period three months after the injection and the increase of degradation products of chlorinated ethenes. Injections of conservative tracers potassium bromide and lithium chloride served as a criterion for differentiation between the process of dechlorination and simple dilution effect. The effectiveness of NZVI-C3 nanoiron and NANOFER STAR with CMC nanoiron were notably lower than the bare NANOFER STAR nanoiron. In...
Comparison of effectiveness of three applications of zero-valent iron nanoparticles for remediation of groundwater polluted by chlorinated ethenes
Vacková, Nikola ; Stejskal, Vojtěch (advisor) ; Oswald, Sascha (referee)
This master's thesis is focused on remediation of groundwater polluted by chlorinated ethenes with a use of nanoiron particles. Three injections of different types of nanoiron were carried out in the contaminated area of Spolchemie a.s. company in Ústí nad Labem. The main aim of the thesis was to compare effectiveness of those three applications. The remediation of groundwater was done by direct- push injection of suspension of nanoscale zero-valent iron. After that a monitoring of groundwater level and physicochemical parameters was performed. Samples of groundwater were collected during the monitoring and were analysed for contaminants and products of dechlorination. It was discovered that NANOFER STAR nanoiron had the strongest influence on reductive dechlorination. This was reflected by concentration decrease of TCE by 84 %, VC by 60 % and total concentration of CHC by 39 % in the period three months after the injection and the increase of degradation products of chlorinated ethenes. Injections of conservative tracers potassium bromide and lithium chloride served as a criterion for differentiation between the process of dechlorination and simple dilution effect. The effectiveness of NZVI-C3 nanoiron and NANOFER STAR with CMC nanoiron were notably lower than the bare NANOFER STAR nanoiron. In...
Modelling dependence of chlorinated hydrocarbons biodegradation on changes of temperature and redox conditions in ATES sytems
Havlíková, Barbora ; Mls, Jiří (advisor) ; Datel, Josef (referee)
The Aquifer Thermal energy Storage (ATES) system is one of the most important techniques, that use the aquifer as an energy storage for heating and cooling the buildings. The operation of the ATES system is based on pumping the cold ground water into the buildings during the summer and then injecting the warmer water back into the aquifer. During the winter, the direction is reversed. Warm water is pumped to the buildings, where it serves for the heating system and then it is injected back into the aquifer. The ATES system has a main effect on the chemical composition of ground water, because of changes in the temperature of ground water, mixing of water from different redox zone and increasing of ground water flow in the neighbourhood of the wells of the ATES system. The modification in chemical composition and temperature could influence the behaviour of contaminants. If we want to install the ATES system into a contaminated aquifer, we have to know, if the ATES system would influence the behaviour of the contaminant plume positively or negatively. This study was made to increase the understanding of the dependence between changes of temperature and oxidation-reduction conditions in the ATES system and biodegradation of chlorinated hydrocarbons. In the first part, several scenarios were modelled...
Groundwater flow and highly permeable zones in aquifers of eastern part of Bohemian Cretaceous Basin based on Litá area and surroundings
Lachman, Vladimír ; Bruthans, Jiří (advisor) ; Vysoká, Helena (referee)
7 Abstract Groundwater flow and highly permeable zones in aquifers of eastern part of Bohemian Cretaceous Basin based on Litá area and surroundings In my thesis I deal with the character of highy permeable zones in marlstones and calcitic sandstones in east-bohemian synclines of the Czech Cretaceous Basin. My chosen area lies southwest of Nové M�sto nad Metují and within it lies Litá area, an important source of groundwater for Hradec Králové region. Groundwater in the area was contaminated in the 80's by chlorinated hydrocarbons. Based on a detailed field sampling of 23 boreholes and 4 sites of surface water performed in 2008 and on archival data on contaminant concentrations, I evaluate the character and relationships of groundwater from the boreholes. I grouped boreholes according to their chemical properties. In the second part of my thesis, I perform the analysis of the influence of faults on groundwater flow in a larger area of east-bohemian synclines. Results show that most yielding boreholes lie between fractures, not near them, which suggests the impermeable role of fractures. From available information I then try to answer the question of highly permeable zones of preferential groundwater flow. Based on the observed flow velocity,...
Komplexní geochemický výzkum interakcí a migrací organických a anorganických látek v horninovém prostředí: Problematika CIU a ropných látek v literatuře
Katedra mineralogie, petrografie a geochemie PřF MU Brno, Brno ; Česká geologická služba, pobočka Brno ; Kabátník, P. ; Konečný, F.
Předkládaná rešerše podává stručný přehled fyzikálních a chemických vlastností vybraných kontaminantů, jejich chování v horninovém prostředí nesaturované a saturované zóny a vliv na zdraví člověka a složky životního prostředí. Pozornost byla zaměřena na alifatické chlorované uhlovodíky (CIU), ropné látky (v parametru NEL - nepolární extrahovatelné látky), bromované těkavé organické látky, polychlorované bifenyly a polyaromatické uhlovodíky.
Komplexní geochemický výzkum interakcí a migrací organických a anorganických látek v horninovém prostředí: Výzkum havarijní kontaminace na lokalitě ELSTAV v Brně - Židenicích
Katedra mineralogie, petrografie a geochemie PřF MU Brno ; Česká geologická služba, pobočka Brno ; Boháček, Z. ; Konečný, F.
Pro realizaci programu byl vybrán areál firmy ELSTAV v Brně. je situován v levobřežní části údolní nivy řeky Svitavy a geologicky je tvořen plastickými jíly neogénního stáří, které svými hydraulickými parametry tvoří bazální izolátor kvartérní zvodně. Byly realizovány vrtné práce, hydrodynamická zkouška, odběry vzorků zemin a podzemní vody a jejich laboratorní rozbory. Na zkoumané lokalitě bylo zastiženo výrazné znečištění horninového prostředí a podzemní vody zejména látkami typu NEL, v menší míře i CIU. Je uveden podrobný komentář, dokumentace a hodnocení realizovaných prací.
Výzkum a pilotní ověřování nových sanačních technologií při odstraňování SEZ
Ekosystem, s.r.o., Praha ; Brož, Martin ; Koubík, Jiří ; Kratochvíl, Miloslav ; Smělý, Ondřej ; Salava, Pavel
Předmětem zprávy je dílčí vyhodnocení 1. etapy projektu výzkumu a pilotního ověřování nových sanačních technologií. Obsahuje i teoretické podklady a odborné informace o sanaci kontaminované zeminy těžkými kovy formou literární rešerše. Zpráva je zaměřena na komplexní rešerše daných témat a posouzení vývoje nejmodernějších dostupných technologií a dále laboratorní ověření těch vybraných metod, jejichž metodiku bude možno extrapolovat pro návrh poloprovozních zkoušek in-situ technologie na vhodné lokalitě v ČR, příp. návrh pilotního zařízení k provádění poloprovozních testů v případě technologie "kapilární třásně".

National Repository of Grey Literature : 13 records found   1 - 10next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.